OptiCross
The OptiCross™ Intravascular Ultrasound (IVUS) catheter is a highly deliverable catheter that physicians rate more deliverable than Volcano Eagle Eye™*, especially in complex lesions.
Product Specifications OptiCross™ vs OptiCross™ 6
|
OPTICROSS |
OPTICROSS 6 |
---|---|---|
Typical Use |
Coronary |
Coronary |
Transducer Frequency |
40 MHz |
40 MHz |
Maximum Diameter Penetration |
6 mm |
6 mm |
Sheath Compatibility (with max wire) |
5F |
6F |
Guide Catheter Compatibility |
5F (ID ≥ 0.058") |
6F (ID ≥ 0.064") |
Guidewire Lumen Length |
16 mm |
16 mm |
Guidewire Compatibility |
≤ 0.014" |
≤ 0.014" |
Entry Profile |
0.026" |
0.017" |
Imaging Window Profile |
2.6F |
2.9F |
Crossing Profile |
3.1F |
3.1F |
Prep Location |
Proximal |
Proximal |
Catheter Telescoping Length |
150 mm |
150 mm |
Sled Pullback Length |
100 mm |
100 mm |
Tip to Transducer Distance |
20 mm |
20 mm |
Distal Marker to Transducer |
15 mm |
15 mm |
Working Length |
135 mm |
135 mm |
Hydrophilic Coating |
Bio-SlideTM |
Z-GlideTM |
Ordering Information
Ref/Catalog Number |
Description |
---|---|
H749518120 |
OPTICROSS™Coronary Imaging Catheter |
H7495181260 |
OPTICROSS™ 6 Coronary Imaging Catheter |
H749A70200 |
Automatic Pullback Sled |
Superior Deliverability5
OptiCross™ has better deliverability than Volcano* & improved image quality2
OptiCross™ Improvements
- 23% shorter tip to transducer length4
- Smallest crossing profile5
- Redesigned Monorail Catheter
5F=1.6mm
Improved Image Quality
Axial Resolution | |
---|---|
Eagle Eye™ Catheter | < 170 micron |
Revolution™ Catheter | 50 micron |
iCross™ Catheter | 43 micron |
OptiCross™ Catheter | 38 micron |
- Axial resolution is important to clearly see stent struts.
OptiCross™ Catheter
Atlantis SR Pro2™ Catheter
- Better axial resolution
- Darker, more apparent lumen
Improved Ease of Use
OptiCross™ Colored Tip: For enhanced visualization during prep
OptiCross™ 1 cm Telescope Marker: Quickly gauge pullback distance
Telescope Improvements
- Extended proximal shaft covers drive cable to reduce entanglement.
- Stiffer telescope reduces likelihood of kinking during imaging core advancement
Atlantis SR Pro2™ Catheter
OptiCross™ Coronary Imaging Catheter
New Hub Design
- "Click" sound with connection
- Reduced potential for connection error
Atlantis SR Pro2™ Catheter
OptiCross™ Catheter
5 French Guide Catheter Compatible
Guide Catheter Compatibility6
Imaging Catheter | |||||
---|---|---|---|---|---|
OptiCross™ Catheter | Atlantis SR Pro2™ Catheter | Eagle Eye™ Catheter | Revolution™ Catheter | ||
Guide Catheter |
Convey Guiding Catheter*** | √ | √ | ||
Launcher Coronary Guide Catheter (Medtronic) |
√ | √ | |||
Heart Rail III Coroary Guiding Catheters (Terumo Medical) |
√ | √ |